Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T12CM07744
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2013 | FRAMING | Approved | ||
| 08/02/2013 | FRAMING | Partial Approval | BIKE STORAGE/LOBBY 4B WAY RECEPT/BUS CENTER & EFFICIENCY UNIT - 1ST FLOOR ONLY |