Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T12CM07499
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2013 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
06/17/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
06/11/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/11/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL APPROX 75'; TRASH ENCLOSURE 2ND LIFT - OK TO GROUT PROGRESS AREAS | |
06/10/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/10/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALLS - APPROX 200'; TRASH ENCLOSURE 1ST LIFT - OK TO GROUT |
|
06/06/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
06/06/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALLS - APPROX 100 L.F; TRASH ENCLOSURE 1ST LIFT - OK TO GROUT PROGRESS AREAS | |
05/31/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/31/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL @ 16' - 20' GL: 5/G-B OK TO GROUT PROGRESS AREA |
|
05/30/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/30/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ 16'-20' GL: H/1-4; ENTRY WALL AT 16'-20' GL: 4-5/G-H; SITE WALLS AT 48" - MID SECTION APPROX 75' - OK TO GROUT PROGRESS AREAS |
|
05/29/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/29/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | WEST CMU WALL AT 16'-20' GL: B/1-5 OK TO GROUT |
|
05/28/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/28/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALL AT 16'-20' - GL: 1/A/H CMU WALL AT 12'-16' - GL: H/1-4; 4-5/G-H OK TO GROUT PROGRESS AREAS |
|
05/24/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
05/24/2013 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | ||
05/21/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/21/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | **CMU WALL AT 13'4" GL: A/1.2; 2/AB (NORTH WALL) CMU WALL AT 16'-GL: B/2-5; 1/A-H OK TO GROUT PROGRESS AREAS **SITE WALL EAST PANEL AT 40' L.F TOPPED-OUT AT 6' - OK TO GROUT |
|
05/15/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/15/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | SITE WALL CMU (EAST) - APPROX 150' AT 48", SOUTH WALL AT 57" - APPROX 200 OK TO GROUT PROGRESS AREAS | |
05/09/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/09/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CMU WALLS @ 8'-11'8": GL: 1/B-H; * *7'4"-8'8" GL; 1/A.8-B; 2/A.8-B - OK TO GROUT |
|
05/06/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/06/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS CMU WALLS - ALL EXTERIOR WALLS AT 4'-8'; OK TO GROUT PROGRESS AREAS | |
05/02/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
05/02/2013 | REINFORCED MASONRY PRE-GROUT | Partial Approval | CONTINUOUS CMU WALLS AT 4'8" A.F.F.E ENSURE ALL RUSTED REBARS ARE REPLACED BEFORE GROUT IS SET |