Permit: T12CM07499

Parcel: 13612001P

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
10/11/2013 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
06/17/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
06/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval SITE WALL APPROX 75'; TRASH ENCLOSURE 2ND LIFT - OK TO GROUT PROGRESS AREAS
06/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval SITE WALLS - APPROX 200'; TRASH ENCLOSURE
1ST LIFT - OK TO GROUT
06/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
06/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval SITE WALLS - APPROX 100 L.F; TRASH ENCLOSURE 1ST LIFT - OK TO GROUT PROGRESS AREAS
05/31/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/31/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL @ 16' - 20' GL: 5/G-B
OK TO GROUT PROGRESS AREA
05/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 16'-20' GL: H/1-4; ENTRY WALL AT 16'-20' GL: 4-5/G-H; SITE WALLS AT 48" - MID SECTION
APPROX 75' - OK TO GROUT PROGRESS AREAS
05/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval WEST CMU WALL AT 16'-20'
GL: B/1-5
OK TO GROUT
05/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 16'-20' - GL: 1/A/H
CMU WALL AT 12'-16' - GL: H/1-4; 4-5/G-H
OK TO GROUT PROGRESS AREAS
05/24/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
05/24/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection
05/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval **CMU WALL AT 13'4" GL: A/1.2; 2/AB (NORTH WALL)
CMU WALL AT 16'-GL: B/2-5; 1/A-H
OK TO GROUT PROGRESS AREAS
**SITE WALL EAST PANEL AT 40' L.F TOPPED-OUT AT 6' - OK TO GROUT
05/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval SITE WALL CMU (EAST) - APPROX 150' AT 48", SOUTH WALL AT 57" - APPROX 200 OK TO GROUT PROGRESS AREAS
05/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS @ 8'-11'8": GL: 1/B-H; *
*7'4"-8'8" GL; 1/A.8-B; 2/A.8-B - OK TO GROUT
05/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CONTINUOUS CMU WALLS - ALL EXTERIOR WALLS AT 4'-8'; OK TO GROUT PROGRESS AREAS
05/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
05/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CONTINUOUS CMU WALLS AT 4'8" A.F.F.E ENSURE ALL RUSTED REBARS ARE REPLACED BEFORE GROUT IS SET