Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 01/15/2013 |
PLUMBING - FINAL |
|
Approved |
IVRS - Inspection :* |
| 01/09/2013 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* AIR TEST OK. CONNECT NEW GAS LINE. PROVIDE SOAP FOR FINAL TEST. 3/8" ID FLEX IS UNDERSIZED. PROVIDE A MIN 1/2" ID GAS FLEX RATED FOR 100,000 BTU DEMAND. 24" CLEARANCE IN FRONT OF HEATER SPECIFIED ON RATING PLATE. |
| 12/27/2012 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 12/19/2012 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* |
| 12/17/2012 |
PLUMBING - FINAL |
|
Not ready for Inspection |
IVRS - Inspection :* SUPPORT ALL PIPING. SEAL HOLES IN ENCLOSURE ROOF. PROVIDE ROOF ACCESS. PROVIDE BTU RATING AND INSTALLATIONINSTRUCTIONS. DATA PLATE BLOCKED FROM VIEW. GAS PIPING MAY BE UNDERSIZED, PROVIDE TOTAL DEVELOPED LENGTH OF PIPING |