Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
Permit Number - T12CM07416
Inspection Description - PLUMBING - YARD WTR LINE/TEST
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2012 | PLUMBING - YARD WTR LINE/TEST | Approved | IVRS - Inspection :* | |
12/04/2012 | PLUMBING - YARD WTR LINE/TEST | Denied | 1. 3" GREY BUILDING DRAIN REQUIRES A 3" CLEANOUT 2006 IRC 3005.29 2. IRC DOES NOT ALLOW A DRY VENT TO OFFSET HORIZANTALLY BELOW THE FICTURE FLOOD LEVEL SEE 3104.4 CORRECT WC VENT 3. REMOVE ALL ROCKS AROUND PIPING AND SHADE WITH CLEAN FILL SEE IRC 2604.1 ALSO READ 2604.3 |