Permit: T12CM07398

Parcel: 141186320


Addresses:

9260 S HOUGHTON RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
01/09/2014 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
11/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
11/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval PALATTE STORAGE EXTERIOR WALLS AT 12' - OK TO GROUT & CAP
10/31/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval TRASH COMPACTOR WALLS - TOPPED OUT AT 10'4" - OK TO GROUT TEMP ENTRY AREA AT 8' - OK TO GROUT PROGRESS AREA
10/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval REINFORCED MASONRY PRE-GROUT. COMPACTOR ENCLOSURE AT 9'4" - OK TO GROUT
10/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval MAIN ENTRY WALLS AT 4'8"; TRASH COMPACTOR WALLS AT 4'8"; PALLET STORAGE AREA WALLS (S & SW) AT 4'8" - OK TO GROUT PROGRESS AREAS
10/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/21/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/21/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CANCELED PER ARMANDO
10/08/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/08/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 5 PILASTERS @ MAIN ENTRY - 14' 4" - OK TO GROUT PROGRESS AREA
10/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval REPAIR BLOCK TO SPLIT-FACE BLOCK GL: C/5.25-5.75 - REPAIR AREA FILLED SOLID WITH MORTAR
10/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/02/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 14' 8" GL: A/8-9; CMU COLUMN AT 13' GL: C/8 - OK TO GROUT PROGRESS AREAS. GARDEN CENTER CLOSET (CMU) AT 16' - TOP-OUT GL: 8/E.5 - OK TO GROUT.
10/01/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
10/01/2013 REINFORCED MASONRY PRE-GROUT Partial Approval GARDEN CENTER - COLUMNS (9) AT 14' 8" GL: 9/A-E.5; A/8.5-9 - OK TO GROUT
09/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval GARDEN CENTER COLUMNS AT 11' 4" (2) GL: A/7.5; A/8-2 - OK TO GROUT PROGRESS AREAS
09/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 3 PILASTERS TOP-OUT AT 16'; NE, SE, & S - OK TO GROUT PROGRESS AREAS
09/26/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/26/2013 REINFORCED MASONRY PRE-GROUT Partial Approval GARDEN CENTER CMU WALLS AT 4' 8" GL: 9/E.75-A.1 A/8.25-9; 9 COLUMNS AT 11" GL: 9/E.75-1; A/8.25-9 SE PILASTER AT 14' - OK TO GROUT PROGRESS AREAS
09/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/25/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 9' 4" - 14' 0" GL: A.1/3.2-4 - OK TO GROUT PROGRESS AREA
09/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/24/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 3 COLUMNS AT 4' 8" GL: A.1/8.5-7.75; CMU WALL AT 9' 4" GL: 3.25/A.1-C - OK TO GROUT
09/23/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/23/2013 REINFORCED MASONRY PRE-GROUT Partial Approval GARDEN CENTER CMU WALL AT 4' 8" GL: 8/A.1-E.75 - 6 PILASTERS AT 9' 4" (SE & S WALLS) - 5 @ 14' (WEST & NW) - OK TO GROUT PROGRESS AREAS
09/20/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CART STORAGE WALL AT 9' 4"; PILASTERS: NORTH & NORTHWEST WALLS: SECOND LIFT; SW, SOUTH, & SE: FIRST LIFT - OK TO GROUT PROGRESS AREAS
09/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/18/2013 REINFORCED MASONRY PRE-GROUT Partial Approval 11 PILASTERS AT FIRST LIFT; NORTHWEST & WEST WALLS; PHARMACY CANOPY AREA PILATER - OK TO GROUT PROGRESS AREAS
09/17/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/17/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 24' 8" GL: B/4.7-6.6; 4.75/B-C (TOP OUT) - OK TO GROUT
09/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 23" 8" GL: 5.3/J-K: K/3.75 - 5.3 - OK TO GROUT
LOADING DOCK WALL AT 2ND LIFT; 10' GL: K/5.3-7 - OK TO GROUT
CMU WALLS AT 23'8"; GL: 5.3/J-K; K/2-3.25; 2/K-L; L/1-2 - GROUTED (SPECIAL INSPECTION SEPT 14TH)
09/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 24' 4" GL: J/5.3-8; CMU WALL AT 23' 8" - 24' 4" GL: K/2-5.3; CMU WALLS AT 19' 4" GL: 2.K-L; L/1-2 - OK TO GROUT PROGRESS AREAS
09/12/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/11/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 14'8" GL: 2/K-L; L/2-1
CMU WALL AT 19'8" - 24'8" GL: K/2-5.3 - OK TO GROUT PROGRESS AREAS
09/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/10/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 18'8" GL: J/5.3-8; K/2-5.3
CMU WALL AT 14': GL: 5.3/J-K; CMU WALL AT 4'8" - GL: K/5.3-7 - OK TO GROUT PROGRESS AREAS
09/09/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
09/09/2013 REINFORCED MASONRY PRE-GROUT Not ready for Inspection CONTRACTOR CANCELED - RAINED OUT
09/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 14' - GL: K/2-5.3; CMU WALL AT 9' 4" - GL: 5.3/J-K - OK TO GROUT PROGRESS AREAS
09/05/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/05/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 23'4" GL: B/4.7-6; WALL AT 22' GL: B/6.1-6.6; CMU WALL AT 14' GL: J/5.3-7; OK TO GROUT PROGRESS AREAS
09/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/04/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 9'4"; GL: K/2-5 AT 9'4" GL: 2/K-L, L/1.5-2
CMU WALL AT 19'4" GL: 1/D.2-E - OK TO GROUT PROGRESS AREAS
09/03/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
09/03/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 19' 4" GL: B/4.7-6.6; 6.6/B-C - OK TO GROUT PROGRESS AREAS
08/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/30/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 19'4" GL:p D.1/6.8-8 - OK TO GROUT PROGRESS AREA: LOADING DOCK WALLS AT 4'8": GL: J/5.3-7; K/2-3.5; OK TO GROUT
08/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/29/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 14' 4"; GL: B-C/3-6.6; GL: 1/D.1-E
08/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/28/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL 19'4" TO TOP-OUT; GL: 1/D.1-L; CMU WALL AT 23'8" GL: C-D.1/1-4; CMU WALL/PILASTER AREA (BEAM) GROUT TO 24" BELOW BEAM; GL: 1/D.1-D.75; OK TO GROUT PROGRESS AREAS.
08/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/27/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 19' - GL: 8/D-E.7 - OK TO GROUT
CMU WALL AT 9'4" GL: C/1-4.8; CMU WALL AT 23'8" GL: 8/E.8-F.9
08/23/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/23/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 18' 8" GL: C-D.1/1-3.9
CMU WALL AT 23' 4" GL: 1/E-L
OK TO GROUT PROGRESS AREAS
08/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/22/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 14' - GL: D.1/7-8; CMU WALL AT 23' 4" GL: 8/F.2/J; CMU WALL AT 18' 4" GL: 1/J.2-L
OK TO GROUT PROGRESS AREAS
08/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/21/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 18' 8" GL: 1/E-J.3 - OK TO GROUT PROGRESS AREA
08/20/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/20/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 14' - 18' 8" GL: 8/G-J
NEED RFI FOR RELOCATION OF EMBEDS OF CONTROL JOINTS.
CMU WALL AT 9' 4" - 14' GL: C-D.1/1-3
OK TO GROUT PROGRESS AREAS
08/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/19/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 14'-18' 8" - GL: 8/D.1-J
VARIOUS BEAM POCKETS IN QUESTION AS TO PROXIMITY TO CONTROL JOINTS
GL: 8/D.1-H - REQUIRE AN RFI FOR VERIFICATION
08/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/16/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 4'8" - 9'4" GL: C-D.1/1-4
CMU WALLS AT 9'4" (PILASTERS) GL: 1/D.2-D.75
CMU WALLS AT 9'4"-14' GL: 1/D.75-L
OK TO GROUT PROGRESS AREAS
08/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/15/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 9'4"-14' GL: 8/D.1-J; CMU WALL AT 9'4" GL: C-D/8.7; CMU WALL AT 0"-56"; GL: 6.8-4.7/D.1-C; CMU WALL AT 4'8"-9'4" GL: 1/K-L; GL: C/1.8-4 - OK TO GROUT PROGRESS AREAS
08/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/14/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 48" GL: 8/G.5-J; CMU WALL AT 4'-8' GL: 1/D.1-L - OK TO GROUT PROGRESS AREA
08/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/13/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALLS AT 48" A.F.F.E. - GL: 1/J.5-L; L/1-1.5;
WALLS AT 4'-8' - GL: 8/D.1-J; D.1/6.8-8
08/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/12/2013 REINFORCED MASONRY PRE-GROUT Partial Approval CMU WALL AT 48" A.F.F.E. GL: C/1-2.8; 1/J.2/-D.1
OK TO GROUT PROGRESS AREAS
08/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/09/2013 REINFORCED MASONRY PRE-GROUT Partial Approval STEM WAlL AT 16" - 48" GL: 1/J.5-K; L/1-15; CMU WALL AT 0" -48" A.F.F.O.; GL: 8/D.1-J; D.1/8-7
OK TO GROUT PROGRESS AREAS
08/08/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/07/2013 REINFORCED MASONRY PRE-GROUT Partial Approval STEM WALLS AT 16"-48" GL: 8/D-L; D-C/8-5; OK TO GROUT PROGRESS AREAS
08/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
08/06/2013 REINFORCED MASONRY PRE-GROUT Partial Approval STEM WALLS AT 16" - 32" GL: 8.G.2-D.1; D.1-C/2.5-8 - OK TO GROUT PROGRESS AREAS