Permit: T12CM07003

Parcel: 115020110


Addresses:

635 E WAVERLY ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T12CM07003

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/13/2013 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
01/24/2013 PLUMBING - ROUGH, SOIL Partial Approval 1. 4" sewer disconnected from existing clay. Don't forget to wrap the pipe before you pour. OK for concrete.
01/18/2013 PLUMBING - ROUGH, SOIL Not ready for Inspection 1. OK for concrete. wrap pipe penetration. Clean-outs to open in the direction of flow. Minimum 4" between trap weir and point of vent. Use a blind plug at cap off below slab. Trap and trap arm to be the same size. Trap arm may not change size. Trap may be only one size larger than the tailpiece to which it is connected. Require 4" cleanout for 4" sewer.