Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T12CM07003
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/13/2013 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 01/24/2013 | PLUMBING - ROUGH, SOIL | Partial Approval | 1. 4" sewer disconnected from existing clay. Don't forget to wrap the pipe before you pour. OK for concrete. | |
| 01/18/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | 1. OK for concrete. wrap pipe penetration. Clean-outs to open in the direction of flow. Minimum 4" between trap weir and point of vent. Use a blind plug at cap off below slab. Trap and trap arm to be the same size. Trap arm may not change size. Trap may be only one size larger than the tailpiece to which it is connected. Require 4" cleanout for 4" sewer. |