Permit: T12CM06746

Parcel: 137292570

Inspection Status: Denied

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
11/14/2013 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/14/2013 PLUMBING - FINAL Denied 1. EXTERIOR COPPER LINES NOT SECURED TO CODE ON EAST EXTERIOR WALL
2. PROTECT INSULATION TO CODE ON 1/2" COPPER LINES FROM UV RAYS. MINIMUM 10 MIL TAPE, SEAL JOINTS TO CODE AND PAINT
3. VACUUM BREAKERS HOSE BIBS
4. ALL INTERIOR WORK COVERED W/O INSPECTION
12/24/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. LINES NEED TO BE SECURED (in accordance with P2605)
2. LINES ABOVE INSULATION ENVELOPE WILL REQUIRE INSULATION