Permit: T12CM06560

Parcel: 13317064C

Inspection Status: Approved

Inspection History: MECHANICAL - ABOVE CEILING

Date Description Inspector Results Comments
12/20/2012 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection :*
Provide access doors for fire dampers. Support expansion tank. Insulate hot water piping. Closet flanges ok. Corridors still need lights. Will chack corrections. Ok for ceiling tiles in rooms, leave out in corridors.
12/19/2012 MECHANICAL - ABOVE CEILING Not ready for Inspection IVRS - Inspection :*
1.VDV CABELING TO BE PER 275.3& 8, 870.3.24, 800.3 &24, 760.3&24
2. rEAPPLY FIRE STOPPING MATERIAL WHERE REMOVED ON TRUSSES
3. FINISH SUPPORT COPPER LINES
4. VERIFY RETURN AIR RATING FOR PLUMBING PIPE WRAP/ INSULATION
5. FINISH INSTALLING LIGHTS
6. SEAL UNUSED ONDUIT OPENINGS
7. FINISH WATER HEATER