Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T12CM06360

Parcel: 122161640


Addresses:

3726 E EDISON ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/11/2012 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
12/07/2012 EXT METAL CLIPS/EXT SHEATHING Denied 1) ADD 2X4 UNDER WEST END OF GIRDER TRUSS AND STITCH ALL THOSE 2X'S
2) USE LIQUID NAILS AT NEW 2X4 LOCATION AND WEDGE TIGHT FROM OUTSIDE.
3) NAIL OFF SAME PIECE OF 25B