Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/25/2013 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 12/24/2012 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 11/26/2012 | MECHANICAL - INTERMEDIATE | Denied | 1) UNIT IS OVER FUSED. (OUT DOOR) 2) HOTLEGS ARE TO BE PROPERLY COLOR CODED (WHITE NOT ACCEPTABLE) 3) CONDUIT FROM DISCONNECT IS IN DIS REPAIR, REPAIR OR RUN NEW CONDUIT TO UNIT. 4) JOINTS AT FLUE PIPE NOT TIGHT/ PROPERLY FITTED 5) CONDENSATE FROM EVAP COIL NOT PROPERLY INSTALLED, PROVIDE 1" AIR GAP AND SUPPORT 6) COMBUSTION AIR NOT CORRECT. 7) PATCH WORK AT UNIT ADAPTOR NOT PROPERLY INSTALLED. |