Permit: T12CM06187

Parcel: 141340120

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Permit Number - T12CM06187

Inspection Description - MECHANICAL - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
03/06/2013 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
03/05/2013 MECHANICAL - INTERMEDIATE Partial Approval IVRS - Inspection :*KIT SINK REQ CO PER PLAN. 2"MIN. CORRECT SLOPE. ISOLATE PLASTIC FROM METAL. PROVIDE APPROVED PIPE SUPPORTS. SEAL INSULATION. 3"WASTE REQ 3"CLEAN OUT. SECURE YOUR CLOSET FLANGES TO FINISHED FLOOR. SEAL FLOOR PENTETRATIONS SEWERS AND SUPPORT GAS PIPING. CHECK PVC VENT MATERIAL W/ INSTALL INSTRUCTIONs. seal vapor barrier get pipes and line set- in walls