Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T12CM06150
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 10/04/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXPOSED NM CABLE ON INTERIOR 2) GROUNDED RECEPTACLES ON NON GROUNDED WIRING 3) KITCHEN RECEPTACLES REPLACED- NEED TO BE GFCI PROTECTED 4) SMOKE DETECTORS NEEDED IN ADDITION BEDROOM AND OUTSIDE OF BEDROOM 5) OUT DOOR RECEPTACLES NOT FOR WET LOCATION (ROOF ALSO) 6) NEW BREAKER MARKED A/C TO BE LISTED FOR USE BY MANUFACTURE 7) POOL EQUIPMENT WIRING IN DETERIORATED AND MISSING CONDITIONS NON CODE COMPLIANT 8) CARPORT WIRING NON CODE COMPLIANT *WATER HEATER FUSE SEPERATED |