Permit: T12CM06069

Parcel: 133220550

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/10/2015 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
02/10/2015 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/10/2015 PLUMBING - ROUGH, SOIL Denied SEWER PIPING REQ TRACE WIRE, REMOVE ROCKS. PUMP CONNECTIONS REQUIRE; A WATER-PROOF ELEC RECEPTOR, A FULL OPEN VALVE, AND A VENT. AAV MAY NOT BE USED; P3114.8, P3114.5, P3114.4. DRAINAGE FITTING REQ AT SUMP DISCHARGE CONNECTION; 3005.2.11, 3007.3.5. ABS MAY NOT BE EXPOSED TO SUN 3007.3.3
**NOTE: YOUR IRRIGATION SYSTEM REQUIRES BACKFLOW PROTECTION**
09/12/2014 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
06/09/2014 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*