Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/10/2015 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 02/10/2015 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 02/10/2015 | PLUMBING - ROUGH, SOIL | Denied | SEWER PIPING REQ TRACE WIRE, REMOVE ROCKS. PUMP CONNECTIONS REQUIRE; A WATER-PROOF ELEC RECEPTOR, A FULL OPEN VALVE, AND A VENT. AAV MAY NOT BE USED; P3114.8, P3114.5, P3114.4. DRAINAGE FITTING REQ AT SUMP DISCHARGE CONNECTION; 3005.2.11, 3007.3.5. ABS MAY NOT BE EXPOSED TO SUN 3007.3.3 **NOTE: YOUR IRRIGATION SYSTEM REQUIRES BACKFLOW PROTECTION** |
|
| 09/12/2014 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/09/2014 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* |