Permit: T12CM05974

Parcel: 141191030

Inspection Status: Partial Approval

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/02/2012 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/28/2012 PLUMBING - INTERMEDIATE Denied SECURE WB AND TUBING, INSTALL WATER HAMMER ARRESTORS. SWEAT CONNECTIONS REQUIRE 18" OF METALLIC TUBING BEFORE CONNECTION TO PEX. SEAL WALL PENN. POOL FILL REQUIRES APPROVED BACK FLOW PROTECTION. HW AND COLD WATER MAY NOT BE BUNDLED TOGETHER. ISOLATE AND SECURE WITH TUBING SUPPORTS.
09/26/2012 PLUMBING - INTERMEDIATE Not ready for Inspection COMPLETE THE WORK CAP OPEN DWV FOR SAFETY PROVIDE ATTIC ACCESS