Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T12CM05817
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/04/2013 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
03/01/2013 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999*UPC 2006 SWEEPS REQUIRED ON VERTICAL TO HORIZONTAL CHANGES. HARD CAPS. FOAM WRAPS. DOUBLE FIX TORE FITTING REQ AT BACK TO BACK FDS, CONNECT TO MAIN WASTE AS SHOWN ON PLAN. 3" VERTICAL WET VENT REQUIRED FOR URINAL CONNECTION |
|
02/27/2013 | PLUMBING - ROUGH, SOIL | Not ready for Inspection |