Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/03/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 09/26/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 09/18/2012 | BUILDING - FINAL | Not ready for Inspection | 1. REAR PORCH EXPOSE FOOTERS TO VERIFY DEPTH 2. 2 BOLTS AT OVERHANG TO RAFTER CONNECTOR 3. LEDGER BOLTS EVERY STUD STAGGERED 1. PROVIDE TREATED PLATES THROUGHOUT EXT SHEET OKT O LATHE |