Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T12CM05675
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/24/2012 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
09/12/2012 | ELECTRIC - FINAL | Denied | 1. MISSING OUTLETS CREATING EXPOSED WIRING 2. MIS-MATCHED FUSES & CIRCUITS IN BUB-PANEL 3. ALL 3 PRONG OUTLETS ON THE 2 WIRE SYSTEM MUST BE CHANGED BACK TO 2 PRONG OUTLETS OR GFI'S 4. NEED SMOKE DETECTORS IN EACH BEDROOM AND HALLWAY PER MANUFACTURER'S SPECS 5. COVER OPEN KNOCK OUT IN MAIN PANEL |