Permit: T12CM05465

Parcel: 133410810

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
02/12/2013 ELECTRIC - FINAL Approved IVRS - Inspection :*
09/12/2012 ELECTRIC - FINAL Denied A SMOKE DETECTOR IS REQUIRED IN THE DOWNSTAIR HALLWAY, ONE IN THE UPSTAIRS HALLWAY & ONE OUTSIDE OF BEDROOM IN THE APARTMENT AREA. THE J BX OUTSIDE IS STILL MISSING THE COVER PLATE. THE OUTDOOR RECEPTACLES STILL ARE NOT GFI PROTECTED. REPAIR THE BROKEN CONDUIT AT THE SOUTH CONDENSINGUNIT & SECURE TO THE WALL.
THE NORTH CONDENSOR HAS EXPOSED WIRING & NOT CONNECTED PROPERLY TO CONDENSOR. SECURE CONDUIT TO WALL. THE BLACK CABLES CONNECTING TO THE CONDENSORS TO FAN COILS NEED TO BE IN CONDUIT & PROPERLY CONNECTED TO CONDENSORS.
09/05/2012 ELECTRIC - FINAL Denied A SMOKE DETECTOR IS REQUIREDIN THE UPSTAIRS HALLWAY, THE DOWNSTAIRS HALLWAY, & OUTSIDE OF THE MASTER BEDROOM.
OUTDOOR RECEPTACLES MUST BE GFI PROTECTED.
J BX AT PATIO MISSING COVER PLATE.
NEED ACCESS TO CONDENSING UNITS ON SIDE OF HOUSE. THERE APPEARS TO BE EXPOSED WIRING AND POSSIBLY NO DISCONNECTS. GATE LOCKED.