Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T12CM05310

Parcel: 141386570

Inspection Status: Approved

Inspection History: ROOF NAILING

Permit Number - T12CM05310

Inspection Description - ROOF NAILING

Inspection Status - Approved

Date Description Inspector Results Comments
10/25/2012 ROOF NAILING Approved IVRS - Inspection :*
10/24/2012 ROOF NAILING Denied -SHIM BEARING TO TOP PLATE OF T-1 TRUSSES, TIB TRUSSES AND ALL OTHERS PER RAFTER SPECS
-416 DETAIL MISSING AT BACK OF HOUSE
- EQUIVILANCY FOR MISSING LSTHD 8 MISSING WEST WALL
- ANCHOR GARAGE/HOUSE WALL SOLE PLATE PER PLAN
-NAIL SHEATHING AT VALLEYS PER 411/SD