Inspection Status: Approved
Inspection History: PLUMBING - YARD WTR LINE/TEST
| Date |
Description |
Inspector |
Results |
Comments |
| 09/06/2012 |
PLUMBING - YARD WTR LINE/TEST |
|
Approved |
IVRS - Inspection :* |
| 09/05/2012 |
PLUMBING - YARD WTR LINE/TEST |
|
Partial Approval |
1. PEX piping not connected at meter. Note: Be sure and keep all piping capped off. 2. See section 306.1 2006 UPC- Buried piping to be supported throughout its entire length. 306.2- Continous load bearing support. Bell holes, hub holes, and coupling holes, shall be provided at points where the pipe is joined. 306.2.2 Rock removal. 306.3 Backfilling., |
| 09/04/2012 |
PLUMBING - YARD WTR LINE/TEST |
|
Not ready for Inspection |
IVRS - Inspection :* |