Permit: T12CM05223

Parcel: 141312070

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T12CM05223

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/08/2012 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/04/2012 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
-LATTERAL BRACING MISSING ABOVE MECHANICAL TRUSSES
-ANCHOR BOLT MISSING GARAGE
-NUT MISSING ON HOLD DOWN AT FRONT
-NAIL DOWN SHEATHING INTO BLOCKING AT ROOF PER 6/PTI
-3 KING STUDS NEEDED AT EACH END OF OVERHEAD DOOR
-15/PTI MISSING BLOCKS AT PLATES
-NAIL OFF SHEATHING AT BIRD BOARDS PER 7/DTI
-NAIL OFF LOOK OUTS AT GABLE ENDS
STOPPED INSPECTION
TOO MANY ITEMS TO LIST