Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T12CM05213

Parcel: 12512312A


Addresses:

3322 E 2ND ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
11/27/2012 ELECTRIC - FINAL Approved IVRS - Inspection :*
11/16/2012 ELECTRIC - FINAL Denied 1. GROUNDING ELECTRODE TO BE TERMINATED TO GROUND TERMINAL CAN NOT USE CAN AS PATH OF GROUND
2. SEAL ENTRANCES ABOVE CURRENT CARRING PART WITH APPROVED DEVICE
3. VERIFY TAP LOG CONNECTOR TO CONDUCTOR SIZES ALLOWED
4. DID NOT RECEIVED PAPERWORK FOR TAP IN METER MAIN
5. FINISH +5 PREVIOUS INSPECTION
11/15/2012 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
10/18/2012 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
09/26/2012 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*