Permit: T12CM05094

Parcel: 120020560


Addresses:

668 W PRESIDENT ST

Inspection Status: Partial Approval

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
08/28/2012 ELECTRIC - RECONNECT Partial Approval IVRS - Inspection :*
08/20/2012 ELECTRIC - RECONNECT Denied 1) SERVICE CANNOT BE PARTIALLY UPGRADED. MIN. RESIDENTIAL INCREASE IS 100AMP PER CODE. NEW 125 AMP SERVICE PANEL WITH 8 NEW 20 AMP CRKT BREAKERS ON OLD 30 AMP METER BASE. ALSO NO MAIN BRKR, RED WIRE NUTS TO SMALL, 30 AMP FUSE DISC. SW NOT APPROVED AS J-BOX. UPGRADE COMPLETE SYSTEM-110.3 NEC.
2) BOND WATER AND GAS PIPING.
3) VERIFY REWIRING OF DWELLING HAS BEEN APPROVED, INSPECTED, PERMIT ON FILE, PLANS?
OBTAIN LICENSED OR QUALIFIED ELECTRICIAN.