Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
08/13/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
08/10/2012 ELECTRIC - RECONNECT Denied REPLACE DAMAGED RECEPTACLE.
PROVIDE A LIGHT GLOBE OVER CLOSET LIGHT.
REMOVE CORD AND PLUG LIGHT ON OUTSIDE OF HOUSE O HARD WIRE.
FILL IN OPEN KNOCKOUT AT PANEL
FILL IN OPEN SPACES IN PANEL DEAD FRONT.
DO NOT SPLICE CONDUCTORS WITH TAPE INSIDE PANEL.
PROVIDE SCREWS IN PANEL DEAD FRONT.
ALL OUTDOOR RECEPTACLES MUST BE GFI PROTECTED.
PROVIDE A ROMEX CONNECTOR AT RECEPTACLE IN CARPORT.
REPLACE ANY MISSING COVER PLATES.