Permit: T12CM04635

Parcel: 138141220


Addresses:

333 W BILBY RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
08/08/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
08/06/2012 PLUMBING - FINAL Not ready for Inspection 1) WATER HEATER AND FURNACE FLUE PIPING IS INSTALLED BACKWARDS
2) CONDENSATE DRAIN CAN NOT BE TIED TO T AND P PIPING AT WATER AGATOR
3) REMOVE TRAP FROM T AND P DRAIN LINE
08/02/2012 PLUMBING - FINAL Denied - GAS LINE MUST BE 12" BELOW FINISHED GRADE. SHALLOW CLOSE TO FENCE AREA
-S-TRAP AT WATER HEATER AND FURNACE REQUIRED
-1"CLEARANCE AROUND COMBUSTIBLES FOR VENT PIPE
-INSPECTOR, BEWARE OF DOGS