Permit: T12CM04635

Parcel: 138141220


Addresses:

333 W BILBY RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
08/08/2012 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
08/06/2012 PLUMBING - GAS PRESSURE TEST Not ready for Inspection 1) WATER HEATER AND FURNACE FLUE PIPING IS INSTALLED BACKWARDS
2) CONDENSATE DRAIN CAN NOT BE TIED TO T AND P PIPING AT WATER AGATOR
3) REMOVE TRAP FROM T AND P DRAIN LINE
08/03/2012 PLUMBING - GAS PRESSURE TEST Denied 1) ISOLATE CONDENSATE LINE AND PRESSURE RELIEF LINES
2) PROVIDE DRIP LEG AT APPLIANCES
3) NO PAPERWORK FOUND
4) PRESSURE TEST AND BURIAL DEPTH OK TO BURY LINE
08/02/2012 PLUMBING - GAS PRESSURE TEST Denied - GAS LINE MUST BE 12" BELOW FINISHED GRADE. SHALLOW CLOSE TO FENCE AREA
-S-TRAP AT WATER HEATER AND FURNACE REQUIRED
-1"CLEARANCE AROUND COMBUSTIBLES FOR VENT PIPE
-INSPECTOR, BEWARE OF DOGS