Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 08/10/2012 |
PLUMBING - ROUGH, SOIL |
|
Approved |
|
| 07/31/2012 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
NEED TO VERIFY ROUGH SOIL FROM PROP. LINE TO MODULAR SEE INSPECTORS NOTES 7-24-12. COVERED PRIOR TO APPROVAL. CUT IN CLEANOUTS. |
| 07/24/2012 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
1. This inspection is for sewer/HCS connection. 4" SDR 35 installed from 8" main to property line cleanout, per std. detail #401 PCWWM. OK to cover subject to material approval. 2. Provide inspection history from property line cleanout to upper terminal cleanout, also bldg. drain to bldg. sewer connection. 3. Provide a stamped letter from the archetect allowing SDR 35 in lieu of solid core sch. 40 PVC as indicated on the plan. |