Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T12CM04119

Parcel: 137321320


Addresses:

1494 W STOCKWELL PL

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/30/2012 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
08/23/2012 EXT METAL CLIPS/EXT SHEATHING Denied COMPLY WITH PREVIOUS NOTES 2,3,5,8,10,&11
08/20/2012 EXT METAL CLIPS/EXT SHEATHING Denied 1) ALL BOTTOM PLATES TO BE PRESSURE TREATED
2) MISSING SW-1 SHEAR WALLS PER PLAN SEE FRAMING PLAN
3) CHECK ALL SHEAR WALL NAILING 6"OC ALL EDGES TO TOP PLATE
4) ALL SW1 SHEAR PANELS TO BE 68" PER CODE NO OPENINGS
5) H-25 CLIPS MISSING NAILS
6) PROUNE LEDGER DETAIL AT FAMILY ROOM SOUTH WALL OR INSTALL LUG BOLTS EACH SUTD STAGGERED
7) MISSING NAILING THROUGHOUT ROD AND SHEATING
8) B-2 TRUSS CALCS SHOW BEARING WALL SOUTH END
9) PROVIDE FOOT TO LEDGER BY MANUFACTURE PROVIDE COT APPROVED CALCS
10) COMPLY WITH TRUSS LAYOUT FAMILY ROOM
11) REMOVE NAILS FROM 2PT BEARING TRUSS B2 TO MID BEARING BED 3 WALL
08/17/2012 EXT METAL CLIPS/EXT SHEATHING Denied PROVIDE COT APPROVED PLANS