Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T12CM03810

Parcel: 140294810


Addresses:

3857 E SUN VIEW CT


Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T12CM03810

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/02/2012 MECHANICAL - FINAL Approved IVRS - Inspection :*
07/27/2012 MECHANICAL - FINAL Partial Approval (1) GAS PIPING NOT PROPERLY SUPPORTED, PANDUITS NOT APPROVED AS PIPE SUPPORT
(2) ALL P.V.C. TO HAVE PRIMER RIOR TO GLUE, PRIMER IS TO BE PURPLE IN COLOR PER U.P.C. HOT GLUE IS NOT ALLOWED WITHOUT PRIMER.
07/19/2012 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*