Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T12CM03776
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2012 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
| 07/17/2012 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 07/16/2012 | PLUMBING - SEWER HCS CONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* SUPPORT SEWER PIPE CONNECT TRACER WIRE TO EXISTING WIRE WITH A WEATHER RESISTANT NUT QUIT SMEARING EXCESS GLUE OVER TRANSITION JOINT. A PROPERTY SOLVENT CEMENTED JOINT IS WIPED TO ALLOW PROPER ? REMOVE ROCKS UNDER AND AROUND WATER TUBING |