Permit: T12CM03718

Parcel: 134090220


Addresses:

8530 E BROADWAY BL


Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T12CM03718

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
03/01/2013 SITE - SEWER Approved IVRS - Inspection :*
11/16/2012 SITE - SEWER Partial Approval IVRS - Inspection :*
11/15/2012 SITE - SEWER Denied IVRS - Inspection :
See detailed listing on site.| 999*
11/14/2012 SITE - SEWER Denied SLOPE LEAK FITTINGS COVERED
11/09/2012 SITE - SEWER Not ready for Inspection POST YOUR ADDRESS. ULITITY PLAN C150 DOES NOT HAVE MECHANICAL PLAN REVIEW. SEE BOB SHERRY. CODE REQUIRES A WATER TEST PRIOR TO COVERING. PROVIDE APPROVED DRAINAGE FITTINGS FOR VENT CONNECTIONS. INSTALL INTERCEPTOR VENT. TEST INTERCEPTOR. CORRECT SLOPE AT CONNECTIONS. PROVIDE THIN WALL BUSHING ON SDR AT TANK OUTLET.
INSTALL CLEANOUTS ON BOTH SIDES OF BW VALVE.