Permit: T12CM03376

Parcel: 113080410


Addresses:

2925 N MITCH DR

Inspection Status: Approved

Inspection History: PLUMBING - YARD WTR LINE/TEST

Date Description Inspector Results Comments
07/30/2013 PLUMBING - YARD WTR LINE/TEST Approved
07/25/2013 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection 1. Tracer wire to be blue. Connected wiring to be made with a waterproof wire nut. Minimum cover for PEX is 12". Hose bibbs require atmospheric vacuum breakers. PEX in the drive requires 18" of cover. Trenches paralleling the footing may not be deeper than the footing unless it is at an angle of fortyfive degrees.
07/18/2013 PLUMBING - YARD WTR LINE/TEST Cancelled IVRS - RI canceled
01/18/2013 PLUMBING - YARD WTR LINE/TEST Not ready for Inspection IVRS - Inspection :*