Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T12CM03319
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2012 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
09/11/2012 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLUMBING NOT COMPLETED |
|
09/10/2012 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLUMBING ITEMS STILL PENDING |
|
09/07/2012 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* PLAN DIAGRAM AND NOTES INDICATE EACH TUB TO BE INDIVIDUALLY VENTED. ALSO CAT RS 3104.4 WC SHALL RISE VERTICALLY TO 6" ABV FLOOD LEVEL. ALL MATERIAL USED SHALL INSTALLED AS SPECIFIES BY THE PRODUCT LISTING. ALL PRODUCTS AND MATERIALS SHALL THIRD PARTY LISES REMOVE P TAPE AT SOLAR ROOG PENETRATION INSTALL CLOSET FLANGES AT FINISHED FLOOR ELEBATOR SUPPORT ALL PIPING: CONDENSATE, DWV AS REQUIRED. PROVEDE MIN DUCT STRAP ON PANS. MIN 1 1/2 REQ FOR FLEX DUCT SUPPORT. SUPPORT LINE SETS. PROVIDE SOLID SUPPORT UNDER HURIZ DRYER VENT. |