Permit: T12CM03319

Parcel: 141388740

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T12CM03319

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/12/2012 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/11/2012 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLUMBING NOT COMPLETED
09/10/2012 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLUMBING ITEMS STILL PENDING
09/07/2012 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
PLAN DIAGRAM AND NOTES INDICATE EACH TUB TO BE INDIVIDUALLY VENTED. ALSO CAT RS 3104.4 WC SHALL RISE VERTICALLY TO 6" ABV FLOOD LEVEL. ALL MATERIAL USED SHALL INSTALLED AS SPECIFIES BY THE PRODUCT LISTING. ALL PRODUCTS AND MATERIALS SHALL THIRD PARTY LISES REMOVE P TAPE AT SOLAR ROOG PENETRATION INSTALL CLOSET FLANGES AT FINISHED FLOOR ELEBATOR
SUPPORT ALL PIPING: CONDENSATE, DWV AS REQUIRED. PROVEDE MIN DUCT STRAP ON PANS. MIN 1 1/2 REQ FOR FLEX DUCT SUPPORT. SUPPORT LINE SETS.
PROVIDE SOLID SUPPORT UNDER HURIZ DRYER VENT.