Permit: T12CM02769

Parcel: 14041127A


Addresses:

6720 S ALVERNON WY

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
12/07/2012 PLUMBING - ROUGH, SOIL Approved
06/13/2012 PLUMBING - ROUGH, SOIL Partial Approval 1. Correction at mop sink made OK. Recall for pre-slab.
06/11/2012 PLUMBING - ROUGH, SOIL Partial Approval 1. Mailbox full 2. Post your address. 3. Where a vent connects to a horizontal drain, it shall have its invert taken off above the drainage centerline downstream of the trap being served. Each vent shall rise at least six inches above the flood rim before offsetting horizontally.. 2. OK to cover the rest.