Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/22/2012 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 05/21/2012 | PLUMBING - GAS PRESSURE TEST | Not ready for Inspection | IVRS - Inspection :* 1) TERMINATE RELIEF DRAIN INTO METAL PAN 2) PROVIDE A 10 PSI TEST WITH A 15 POUND GAUGE 3) PVC AND FLASHING |
|
| 05/17/2012 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) RELIEF VALVE MAY NOT HAVE TRAP 2) RELIEF VALVE IS NOT OPERABLE 3) VENTING REQUIRES CORRECT USE OF FITTINGS, WITH JOINTS SECURED WITH GALVANIZED FASTENERS 4) EXTERIOR PIPING REQUIRES SUPPORT 5) NEW HEAT PUMP REQUIRES A PERMIT 6) ROOF PENETRATIONS ARE NOT PROPERLY FLASHED |