Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T12CM02710
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/06/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 05/23/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GFI IN KITCHEN LOOSE 2) RISER STRAP TO LOW FROM WEATHER HEAD AT SERVICE 3) GUEST HOUSE NORTH EAST CORNER LIGHT NOT WIRED TO CODE 4) GUEST HOUSE WATER HEATER FLEX MISSING BUSAHING AT END AND DISCONNECT AT BREAKER 5) PIPE RUN FROM SERVICE TO SUB PANEL TO BE STRAPPED 6) WIRE FEEDING SUB PANEL TO SMALL 7) ELECTRICIAN TO CORRECT THESE VIOLATIONS 8) ALSO GUEST HOUSE TO BE OPENED FOR INSPECTION |