Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/28/2012 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 06/25/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* | |
| 06/22/2012 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 06/20/2012 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* WATER HEATER RELIEF DRAIN HAS BACK PITCH KITCHEN SINK MISSING CLIPS SECURE DISH WASHER DRAIN HOSE TO UNDER SIDE OF COUNTER APPROVED PIPES CLAMPS PROMPERLY INSTALLED STOVE MISSING VACUUM BREAKERS CONDENSATE CONNECTION TO MECHANICAL UNIT IS NOT PROPERLY INSTALLED AND YOU ARE MISSING AN OVER FLOW SENSOR. CHECK FOR IMPROPER WIRING AT FURNACE ELECTRICAL BOX. VERIFY THAT ALL REQUIRED GFCI OUTLETS ARE IN PLACE. PROTECT INE SET INSULATION FROM UV PROVIDE ROOF ACCESS FOR FINAL INSP |