Permit: T12CM02470

Parcel: 135051860

Inspection Status: Approved

Inspection History: BUILDING - PROGRESS

Date Description Inspector Results Comments
07/11/2012 BUILDING - PROGRESS Approved IVRS - Inspection :*
05/22/2012 BUILDING - PROGRESS Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CORRECT WIRES NOT IN CONDUIT AT MAIN PANEL AND IDENTIFY WHAT THEY SERVICE
2) IDENTIFY CIRCUITS IN GARAGE SUB PANEL AND FILL OPEN KNOCKOUT IN PANEL
3) PATIO SUB PANEL-IDENTIFY CIRCUITS AND SEPERATE NEUTRALS AND GROUNDS
4) IDENTIFY GAS LINE IN GARAGE FROM WHERE ? AND SIZE & RUN
5) ZIP CORD IN N.E. GARAGE OUTLET-MAKE ALL 110 DUPLEX OUTLETS GFI
6) INSTALL FIRE WALLS/CEILING IN GARAGE TO 3' FROM PROPERTY LINE