Permit: T12CM02421

Parcel: 119042240


Addresses:

3669 S LIBERTY AV

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
12/14/2012 MECHANICAL - FINAL Approved IVRS - Inspection :*
12/12/2012 MECHANICAL - FINAL Partial Approval 1) FLUE PIPE NEEDS MIN. 3 SCREWS PER JOINT REMOVE TAPE
2) WATER HEATER DRAIN PAN NEEDS PLUG
3) PROVIDE BACK DRAFT PAMPER AT RANGE HOOD.
4) PVC TO HAVE PRIMORED JOINTS, PROVIDE SECONDARY DRAIN AT AC COIL
5) PROVIDE BUSHINGS FOR T-STAT WIRE
6) OUTDOOR LINE SET INSULATION TO BE U.V. PROTECTED.
7) OUTDOOR T-STAT WIRE TO BE IN PROTECTING CONDUIT BUILDING FINAL NOT READY SEE HISTORY