Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T12CM02250
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
04/27/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED SMOKE DETECTORS IN BEDROOMS 2) BATHROOM RECEPTS TO BE GFCI PROTECTED 3) REMOVE GROUNDING EQUIPMENT CONDUCTOR FROM NEUTRAL BAR AND CLEAN EXCESS FOREIGN MATERIAL AND DIRT FROM SUB PANEL 4) KITCHEN UNDER COUNTER LIGHT NOT WIRED CODE COMPLIANT |