Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/11/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 05/09/2012 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CORRECT SLOPE, REMOVE ROCKS AND EXPOSE PIPE AND FITTINGS COVERED WITH DIRT 2) SHADE PIPE, BUT DO NOT BURY JOINTS PRIOR TO INSPECTION 3) RED LINE REVISED PLAN WITH AS BUILT DIMENSIONS 4) PEX OK 5) COPPER JOINTS HAVE NOT BEEN CORRECTED 6) HAVE PLUMBER ON SITE TO ? A JOINT AT RANDOM TO PROVIDE CODE COMPLIANCE |
|
| 05/07/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* |