Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T12CM02142

Parcel: 141311860

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
05/11/2012 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/09/2012 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CORRECT SLOPE, REMOVE ROCKS AND EXPOSE PIPE AND FITTINGS COVERED WITH DIRT
2) SHADE PIPE, BUT DO NOT BURY JOINTS PRIOR TO INSPECTION
3) RED LINE REVISED PLAN WITH AS BUILT DIMENSIONS
4) PEX OK
5) COPPER JOINTS HAVE NOT BEEN CORRECTED
6) HAVE PLUMBER ON SITE TO ? A JOINT AT RANDOM TO PROVIDE CODE COMPLIANCE
05/07/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*