Permit: T12CM02023

Parcel: 11904243C


Addresses:

213 W 44TH ST #01

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
04/24/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
04/20/2012 ELECTRIC - RECONNECT Partial Approval IVRS - Inspection :*
1) WE STILL HAVE GROUNDED RECEPTS ON NON GROUNDED CIRCUITS
2) TIGHTEN LOOSE FITTINGS
04/18/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RESUPPORT XONDUIT & GROUND WIRE TO STRUCTURES
2) BACK OUTSIDE LIGHT FALLING OFF WALL
3) SMOKE DETECTORS REQUIRED IN HALLWAY & BERDROOMS - 6"-12" BELOW CEILING - 3' AWAY FROM COOLER VENT.
4) CHECK OUT MIX MATCH RECEPTACLES SOME GROUNDED SOME NOT. ALSO RECOMMEN GFI PROTECTED RECEPTS AT KITCHEN COUNTER
5) DISCONNECT SMALL UNIT IN BACK OR BRING UP TO CODE