Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T12CM02000
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/08/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
08/07/2012 | ELECTRIC - RECONNECT | Denied | SMOKE DETECTORS MUST BE BETWEEN 6'-12" BELOW CEILING TO DETECT SMOKE PROPERLY. | |
07/24/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* ITEMS NUMBERS 4, 2, 1, 3, 6, 7, 8 ONLY 2 OF 9 ITEMS CORRECTED DATED 6-28-12 A RE-FEE IS BEING ATTACHED TO THIS PERMIT |
|
06/28/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SEAL TITE FROM PANEL INTO GARAGE NOT TO CODE 2) PVC CONDUIT AT EXTERIOR NOT PROPERLY SUPPORTED 3) DOOR AT ELEC PANEL BREAKEN OFF 4) BARE WIRES HANGING OUT OF WALL IN LAUNDRY ROOM, PROVIDE APPROVED SWITCH COVERS IN LAUNDRY ROOM, TAPE NOT ACCEPTABLE 5) BARE WIRES HANGING OUT OF WALL ON REAR PORCH 6) EXTERIOR OUTLET COVERS BROKEN 7) SMOKE ALARMS REQUIRED IN BEDROOMS 8) BARE WIRES IN FURNACE ROOM 9) BARE WIRES HANGING OUT OF WALLLS AND CIELING IN GARAGE |