Permit: T12CM01966

Parcel: 107051080


Addresses:

2928 N 15TH AV #27


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T12CM01966

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
05/01/2012 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
04/18/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OPEN WIRING SPLICES
2) PLEASE VERIFY PERMITS FOR RB WIRING OF MOBLE HOME
3) CORDS OTHER THAN LIFELINE NOT ALLOWED FOR PERMANENT WIRING
4) GROUNDING & CORRECTIONS AT PANEL NOT CODE COMPLIANT
5) BREAKER TO BE LISTED FOR USE BY MANUFACTURE
6) SMOKE DETECTOR TO BE INSTALLED PER MANUFACTURES INSTRUCTIONS
7) WATER HEATER NOT ELECTRICLY CODE COMPLIANT - CONCERNS ALSO OVER PLUMBING CONNECTIONS
* NOTE NEW WIRE DATED JUNE 2004
ALSO STRUCTIAL ISSUES OVER NEW PORCH/ENTRY AND ROOM REMODELING