Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T12CM01966
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2012 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
04/18/2012 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OPEN WIRING SPLICES 2) PLEASE VERIFY PERMITS FOR RB WIRING OF MOBLE HOME 3) CORDS OTHER THAN LIFELINE NOT ALLOWED FOR PERMANENT WIRING 4) GROUNDING & CORRECTIONS AT PANEL NOT CODE COMPLIANT 5) BREAKER TO BE LISTED FOR USE BY MANUFACTURE 6) SMOKE DETECTOR TO BE INSTALLED PER MANUFACTURES INSTRUCTIONS 7) WATER HEATER NOT ELECTRICLY CODE COMPLIANT - CONCERNS ALSO OVER PLUMBING CONNECTIONS * NOTE NEW WIRE DATED JUNE 2004 ALSO STRUCTIAL ISSUES OVER NEW PORCH/ENTRY AND ROOM REMODELING |