Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T12CM01942
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/30/2013 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/18/2013 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* | |
07/18/2013 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | EXTERIOR OK TO COVER. HEADER SIZE NEEDS RESOLUTION. IF CHANGING HEADERS, NAILING TO BE RETURNED TO ORIGINAL. - ACCORDING TO IRC TABLE 502.5.1 NOTED FROM LETTER FROM BURCE DAWSON ARCHITECT, WINDOW HEADERS ARE OVERSPANNED. KEN VAN KARSEN FROM PLAN REVIEW CONFIRMING OVERSPAN. - HEADERS ON NORTH SIDE OF GARAGE NOT ON FRAMING PLAN, PLEASE ADD. |
|
06/27/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
06/27/2013 | EXT METAL CLIPS/EXT SHEATHING | Denied | - HEADER SCHEDULE NEEDED FOR WINDOW & DOOR OPENINGS AT EXTERIOR - REVISION NEEDED FOR REPLACEMENT OF TERMITE INFESTED WALL - POST A BEAM SCHEDULE W/ RAFTER SIZE NEEDED FOR SOUTH PORCH |
|
04/09/2013 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* |