Permit: T12CM01932

Parcel: 11618432G

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T12CM01932

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
05/25/2012 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
05/24/2012 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1) GREASE TRAP AT PRODUCE INSTALLED OK
2) OK TO COVER UNDERGROUND
05/23/2012 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) EACH FIXTURE TRAP TO HAVE A VENT. SEE REVIEWERS NOTE
2) THERE MAYBE NO SYSTEM VENT BETWEEN THE FLOW CONTROL AND THE GREASE TRAP. FLOW CONTROL MAY NOT BE BUSHED
3) ALL VENTS TO EXTEND VERTICALLY AT LEAST 6" ABOVE OVER FLOW BEFORE OFF SETTING HORIZONTALLY
05/18/2012 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
GW WITH INTOCEPTOR INSTALLATION AND IN WALL PIPING, OK @ MONT DEPT