Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/25/2012 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 05/24/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1) GREASE TRAP AT PRODUCE INSTALLED OK 2) OK TO COVER UNDERGROUND |
|
| 05/23/2012 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 1) EACH FIXTURE TRAP TO HAVE A VENT. SEE REVIEWERS NOTE 2) THERE MAYBE NO SYSTEM VENT BETWEEN THE FLOW CONTROL AND THE GREASE TRAP. FLOW CONTROL MAY NOT BE BUSHED 3) ALL VENTS TO EXTEND VERTICALLY AT LEAST 6" ABOVE OVER FLOW BEFORE OFF SETTING HORIZONTALLY |
|
| 05/18/2012 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* GW WITH INTOCEPTOR INSTALLATION AND IN WALL PIPING, OK @ MONT DEPT |