Permit: T12CM01774

Parcel: 131091220


Addresses:

5712 E 26TH ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
04/17/2012 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection :*
04/12/2012 PLUMBING - GAS PRESSURE TEST Not ready for Inspection IVRS - Inspection :*
1) WATER HEATER FLUE PIPE MUST HAVE A MINIMUM OF 1" CLEARANCE TO COMBUSTIBLE MATERIAL
2) FLUE PIPE NOT PROPERLY INSTALLED
3) ROOF JACK REQUIRED FOR ALL ROOF PENETRATIONS, PROVIDE ROOF JACK WHERE GAS PIPE ENTERS ATTIC SPACE
4) FURNACE FLUE PIPE MUST HAVE PROPER CLEARANCE TO COMBUSTIBLES
5) MINIMUM HOUSING REQIREMENTS REQUIRE ALL DWELLINGS TO HAVE AN ABILITY TO COODE, THESE UNITS PROVIDE NO MEANS (GAS OR ELECTRIC) FOR A STOVE, THIS MUST BE DONE PRIOR TO OCCUPANCY