Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T12CM01724
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2012 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
05/23/2012 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BELLY BAND WEST SIDE NOT NAILED INTO 2ND FLOOR BOTTOM PLATE 2) 3 TRIMMERS AT END OF (2) WINDOWS BACK WALL 3) NAIL OFF FRONT LEDGER PER 346/SD 4) LUS44 NEEDED IN GARAGE CANTILEVERED FLOO0R 5) POST CAPS AT FRONT PORCH PER PLAN (601/SP) 6) STRAP PATIO BEAM AT BACK PATIO PER PLAN 602/SD 7) STOPPED INSPECTION; TO MANY ITEMS |