Permit: T12CM01595

Parcel: 13707235A


Addresses:

5143 S MONTANA PL

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
10/15/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
10/10/2012 PLUMBING - FINAL Partial Approval 1) COMBUSTION OUTLET/ INLET TO BE WITHIN 12" OF CEILING.
2) V.B. ON FRONT HOSE BIBB.
3) PROVIDE ARC FAULTS.
4) PLUG HOLES IN PORCH LIGHT BOX.
5) SUPPORT W.H. FLUE PIPE.
10/08/2012 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
KEY DOES NOT FIT SECURITY DEAD BOLT. NO ACCESS.
10/03/2012 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT UNDER CABINET
2) DRIP LEG WATER HEATER
3) VACUUM BREAKER HOSE BIBB
4) PROVIDE 100 CU INCH COMBUSTION RELIEF WATER HEATER ROOM
09/28/2012 PLUMBING - FINAL Not ready for Inspection CANCELLED