Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/15/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 10/10/2012 | PLUMBING - FINAL | Partial Approval | 1) COMBUSTION OUTLET/ INLET TO BE WITHIN 12" OF CEILING. 2) V.B. ON FRONT HOSE BIBB. 3) PROVIDE ARC FAULTS. 4) PLUG HOLES IN PORCH LIGHT BOX. 5) SUPPORT W.H. FLUE PIPE. |
|
| 10/08/2012 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* KEY DOES NOT FIT SECURITY DEAD BOLT. NO ACCESS. |
|
| 10/03/2012 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT UNDER CABINET 2) DRIP LEG WATER HEATER 3) VACUUM BREAKER HOSE BIBB 4) PROVIDE 100 CU INCH COMBUSTION RELIEF WATER HEATER ROOM |
|
| 09/28/2012 | PLUMBING - FINAL | Not ready for Inspection | CANCELLED |