Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T12CM01550
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2012 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
06/18/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* INSTALL BATH MIRROR 40" MAX HEIGHT |
|
06/14/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE NEW MECH PLAN FROM ENGINEER OF RECORD OR BUILD TO APPROVED PLAN MECHANICAL 2) UNABLE TO LOCATE APPROVED PLAN FOR CHANGES @ GREASE TRAP SEE NOTES 2/22/12 3) CLOSET FLANGE OK NEXT NOT READY MAY RESULT IN A REFEE |
|
05/22/2012 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) PROVIDE APPROVED PLAN FOR CHANGES AT GREASE TRAP 2) ABS DWV OK 3) WATER INSULATION OK 4) OK TO COVER WALLS |
|
05/21/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) SUBMIT NEW PANEL SCHEDULE OR BUILD TO PLAN |
|
05/08/2012 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) DELTA REVISION FOR ADDED HAND SINK OK 2) OK TO BACKFILL WITH CLEANFILL, EXCEPT AROUND G.T. 3) FLOW CONTROL MAY NOT BE INSTALLED UNDERGROUND 4) EACH FIXTURE CONNECTED TO A HYDRO MECHANICAL INTERCEPTOR SHALL HAVE FLOW CONTROL, INSTALLED AND READILY ACCESSIBLE AND VISIBLE LOCATION |